Flow Analysis Equipment - List of Manufacturers, Suppliers, Companies and Products

Flow Analysis Equipment Product List

1~11 item / All 11 items

Displayed results

Seawater Nutrient Measurement Device Quattro

Low concentrations of nitrate, ammonia, phosphate, and silica in seawater can be measured. (Continuous flow analysis method is used.)

It is used by government agencies and marine research institutions at universities. It can measure up to five items simultaneously—nitrate, nitrite, phosphate, ammonia, and silica—at a rate of 120 samples per hour. It is capable of measuring ultra-low concentrations of nutrients. 【Features】 ■ High precision and high sensitivity analysis based on a bubble segmentation continuous flow method ■ The main console can accommodate four colorimeters ■ By adding extra colorimeters, simultaneous analysis of up to five items is possible ■ Standard equipped with an auto-sampler that holds 120 samples ■ Capable of measuring ultra-low concentrations of nutrients *For more details, please refer to the PDF document or feel free to contact us.

  • Other measuring instruments
  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Analysis examples of fluorine and cyanide using Continuous Flow Analysis (CFA method)

Introduction to case studies on the analysis of fluoride and cyanide using an autoanalyzer!

This document presents a case study on the analysis of fluoride and cyanide using Continuous Flow Analysis (CFA) as part of customer feedback. Mitsubishi Material Tech Corporation has long utilized Continuous Flow Analysis (CFA) equipment to measure fluoride and cyanide in soil and wastewater. In addition to examining the benefits and issues of using our auto-analyzer "swAAT," we have also compared the inter-laboratory reproducibility of cyanide analysis among various institutions and provided an introduction to these findings. [Contents] ■ Benefits of utilizing the auto-analyzer ■ Time reduction and multi-sample measurement through continuous flow analysis ■ Error reduction through flow analysis ■ Method comparison through joint experiments (cyanide) ■ Baseline changes due to room temperature ■ Maintenance examples *For more details, please refer to the PDF document or feel free to contact us.

  • Other analytical equipment
  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Examples of the use of Continuous Flow Analysis (CFA method) in environmental analysis, among others.

Examples of the use of CFA method in environmental analysis and efforts for the restoration of Lake Shinji.

This document introduces the case study of the use of auto analyzers in environmental analysis by Daifuku Industrial Co., Ltd., as well as their efforts towards the environmental restoration of Lake Shinji. The auto analyzer adopted by our company is "SYNCA." In addition to a report comparing the analysis of hexavalent chromium in improved soil according to JIS K 0170-7 and JIS K 0102 65.2.1, it also includes a discussion on the impact of intermittent low oxygen levels in shallow areas on the survival of Yamato shijimi clams as part of the efforts for the restoration of Lake Shinji. [Contents] ■ Case study of the use of auto analyzers (SYNCA: hexavalent chromium) in environmental analysis - Analysis method - Equipment and overview - Summary of results ■ Efforts towards the environmental restoration of Lake Shinji (Impact of continuous low oxygen levels in shallow areas on the survival of Yamato shijimi clams) - Materials and methods - Results and discussion *For more details, please refer to the PDF document or feel free to contact us.

  • Other analytical equipment
  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

"Analysis Work Efficiency Improvement WEB Online Seminar" *Free Participation*

We propose work efficiency improvements using Continuous Flow Analysis (CFA) and Near Infrared Analysis (NIR) devices. We will also introduce some examples.

Our company, engaged in the development, manufacturing, and sales of analytical instruments, will hold a "Web Online Seminar on Streamlining Analytical Work." We will introduce the "Continuous Flow Analyzer (CFA)," which has become the standard method for environmental analysis, the "Acid Decomposition Pretreatment Device" capable of heating up to 300°C, and the "Near Infrared Analyzer" that can analyze caloric content, protein, fat, carbohydrates, and salt equivalent in about 30 seconds. The seminar consists of three parts, and you can participate in any one of them. Participation is free (pre-registration required). We will also propose ways to improve efficiency using real examples. 【Seminar Overview】 Date: July 3, 2020 (Friday) Part 1 at 13:00, Part 2 at 14:00, Part 3 at 15:00 Cost: Free (pre-registration required) How to apply: Please register at http://www.bl-tec.co.jp/ (Registration will start on June 19) *You can view detailed materials for this seminar via PDF download. Please feel free to contact us with any inquiries.

  • Measurement and Analysis Equipment
  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Case study of measuring fluorinated compounds in factory wastewater using Continuous Flow Analysis (CFA) method.

Introduction of a case study on the measurement of fluorinated compounds in factory wastewater using Continuous Flow Analysis (CFA) method.

This document introduces a case study on the measurement of fluoride in factory wastewater using the continuous flow analysis method (CFA method) as per JIS K 0102 34.4. Contents ■ Overview of the analysis ■ Introduction of the equipment ■ Actual measurement case ■ Results of recovery rate *For more details, please refer to the PDF document or feel free to contact us.

  • Other measuring instruments
  • Water treatment technology and systems
  • Water quality/pH measuring device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

River and Lake Nutrient Measurement Device - SWAT

Nitrate, ammonia, phosphate, and silica in environmental water, wastewater, and sewage can be measured. (Continuous flow analysis method is used)

It is used by government agencies, universities, and private water quality testing organizations. It can simultaneously measure up to five items: nitrate, nitrite, phosphate, ammonia, and silica, at a rate of 120 samples per hour. It is capable of a wide range of measurements, including rivers, brackish water, lakes, and environmental water. 【Features】 - Simultaneously measures up to five items: nitrate, nitrite, phosphate, ammonia, and silica, at a rate of 120 samples per hour. - Capable of a wide range of measurements, including rivers, brackish water, lakes, and environmental water. - Excellent automation techniques. - Outstanding cost performance. - Listed in JIS and Ministry of the Environment notification laws. *For more details, please refer to the PDF materials or feel free to contact us.

  • Other measuring instruments
  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

An analysis case using the CFA method for measuring nitrogen and phosphorus in seawater, etc.

Publication of case studies using the CFA method for measuring total nitrogen and total phosphorus in seawater and wastewater.

The nitrogen and phosphorus analysis using the auto-analyzer from Sanyo Technomarine Co., Ltd. adopts the Continuous Flow Analysis (CFA) method, and we are currently using our "QuAAtro2-HR." When introducing flow analysis methods, the focus is generally on improving efficiency, but after implementation, users face unique challenges and innovations in equipment management. This document reports on the insights gained by Sanyo Technomarine Co., Ltd. as a user. 【Contents】 ■ Overview of the analysis equipment Analysis methods and specifications of the equipment in use ■ Comparison of this model with manual analysis Comparison of manual analysis and CFA from the perspectives of "effectiveness" and "burden" ■ Contamination prevention measures in NH4-N analysis Contamination prevention measures using soundproof boxes, etc. ■ Measures against carryover in total nitrogen analysis ■ Summary *For more details, please refer to the PDF document or feel free to contact us.

  • Other analytical equipment
  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Continuous Flow Analysis System (CFA) "MiSSion"

Equipped with halogen and LED light sources! Vertical two-channel system of the auto analyzer series.

We have newly released the continuous flow analysis device "MiSSion." It is a vertical two-channel system from the auto-analyzer series. The measurement principle is based on the flow analysis device using the absorbance method, specifically the bubble segment type "CFA" method. The auto-analyzer series offers over 1,000 analytical methods for chemical analysis in various fields such as environment, agriculture, fisheries, and chemistry, and is widely used in many analytical institutions. 【Features】 ■ Supports ultra-low concentration measurements ■ Can be equipped with halogen and LED light sources ■ Excellent maintainability ■ Temperature control function for the detector ■ New software *For more details, please refer to the PDF document or feel free to contact us.

  • Other analytical equipment
  • Measurement and Analysis Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[JASIS Kansai 2025 Exhibition] Displaying analytical instruments for the environmental and food industries!

Exhibiting at "JASIS Kansai 2025," where technologies related to science and analysis come together! A wide range of products that assist in automation, from pre-treatment to measurement of the environment and food, will be showcased.

"JASIS Kansai 2025" is a science and analysis system and solutions exhibition that gathers numerous manufacturers of analytical and scientific instruments that support the advancement of science beneficial to people's lives. Many presentations and seminars on new technologies will be held. Our company, which contributes to the automation of environmental and food analysis and the improvement of efficiency and quality through analytical instruments, will showcase a variety of products, including "Heavy Metal Analysis Pretreatment Equipment" and "Near Infrared Analysis Equipment." Please feel free to visit us. [Exhibited Products] ■ Continuous Flow Analysis Device 'MiSSion' ■ Fully Automatic Acid Decomposition Pretreatment Device 'AATM' ■ Fully Automatic Acid Decomposition Pretreatment Device 'DEENA2' ■ Near Infrared Analysis Device 'SpectraStar XT' ■ Damaged Starch Measurement Device 'SDmatic 2' *For details on the exhibited products, please refer to the <PDF download>. For more information on various products, please contact us.

  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Fluorine, cyanide, and phenol measurement device Swat

Cyanide, fluoride, and phenol in environmental water can be measured (using continuous flow analysis method).

It is used by public institutions and private measurement certification businesses for water quality testing. Measurements for items requiring distillation can be conducted at a rate of 20 samples per hour. It is equipped with a fully automatic distillation device. 【Features】 - Measurements for items requiring distillation can be conducted at a rate of 20 samples per hour - Incorporates a fully automatic distillation device - Excellent automation technology - Outstanding cost performance - Listed in JIS and Ministry of the Environment notification laws *For more details, please refer to the PDF document or feel free to contact us.

  • Other measuring instruments
  • Other analytical equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Cooling Water Measurement Device Quattro

The hardness, alkalinity, sulfate ions, silica, and iron ions of the cooling water cooling tower can be measured. (Continuous flow analysis method is used.)

It is used by companies that manufacture and manage cooling towers. It can measure multiple items simultaneously, with a capacity of 80 samples per hour. 【Features】 - High precision and high sensitivity analysis based on the principle of bubble segmentation continuous flow method - Capable of mounting four colorimeters on the main console - Can measure multiple items simultaneously, with a capacity of 80 samples per hour - Standard equipped with an auto-sampler that holds 120 tubes - Economical due to low consumption of samples and reagents *For more details, please refer to the PDF document or feel free to contact us.

  • Other analytical equipment
  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration